Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 20
1.
J Mater Chem C Mater ; 12(15): 5339-5346, 2024 Apr 18.
Article En | MEDLINE | ID: mdl-38645749

Organic electrochemical transistors (OECTs) have emerged as promising candidates for various fields, including bioelectronics, neuromorphic computing, biosensors, and wearable electronics. OECTs operate in aqueous solutions, exhibit high amplification properties, and offer ion-to-electron signal transduction. The OECT channel consists of a conducting polymer, with PEDOT:PSS receiving the most attention to date. While PEDOT:PSS is highly conductive, and benefits from optimized protocols using secondary dopants and detergents, new p-type and n-type polymers are emerging with desirable material properties. Among these, low-oxidation potential oligomers are highly enabling for bioelectronics applications, however the polymers resulting from their polymerization lag far behind in conductivity compared with the established PEDOT:PSS. In this work we show that by careful design of the OECT geometrical characteristics, we can overcome this limitation and achieve devices that are on-par with transistors employing PEDOT:PSS. We demonstrate that the vertical architecture allows for facile electropolymerization of a family of trimers that are polymerized in very low oxidation potentials, without the need for harsh chemicals or secondary dopants. Vertical and planar OECTs are compared using various characterization methods. We show that vOECTs are superior platforms in general and propose that the vertical architecture can be expanded for the realization of OECTs for various applications.

2.
Langmuir ; 39(23): 8196-8204, 2023 06 13.
Article En | MEDLINE | ID: mdl-37267478

Seamless integration between biological systems and electrical components is essential for enabling a twinned biochemical-electrical recording and therapy approach to understand and combat neurological disorders. Employing bioelectronic systems made up of conjugated polymers, which have an innate ability to transport both electronic and ionic charges, provides the possibility of such integration. In particular, translating enzymatically polymerized conductive wires, recently demonstrated in plants and simple organism systems, into mammalian models, is of particular interest for the development of next-generation devices that can monitor and modulate neural signals. As a first step toward achieving this goal, enzyme-mediated polymerization of two thiophene-based monomers is demonstrated on a synthetic lipid bilayer supported on a Au surface. Microgravimetric studies of conducting films polymerized in situ provide insights into their interactions with a lipid bilayer model that mimics the cell membrane. Moreover, the resulting electrical and viscoelastic properties of these self-organizing conducting polymers suggest their potential as materials to form the basis for novel approaches to in vivo neural therapeutics.


Lipid Bilayers , Polymers , Animals , Polymerization , Cell Membrane , Membranes , Mammals
3.
Science ; 379(6634): 795-802, 2023 02 24.
Article En | MEDLINE | ID: mdl-36821679

Interfacing electronics with neural tissue is crucial for understanding complex biological functions, but conventional bioelectronics consist of rigid electrodes fundamentally incompatible with living systems. The difference between static solid-state electronics and dynamic biological matter makes seamless integration of the two challenging. To address this incompatibility, we developed a method to dynamically create soft substrate-free conducting materials within the biological environment. We demonstrate in vivo electrode formation in zebrafish and leech models, using endogenous metabolites to trigger enzymatic polymerization of organic precursors within an injectable gel, thereby forming conducting polymer gels with long-range conductivity. This approach can be used to target specific biological substructures and is suitable for nerve stimulation, paving the way for fully integrated, in vivo-fabricated electronics within the nervous system.


Biopolymers , Brain , Electric Conductivity , Enzymes , Peripheral Nervous System , Animals , Biopolymers/biosynthesis , Brain/enzymology , Electrodes , Electronics , Enzymes/metabolism , Leeches , Models, Animal , Peripheral Nervous System/enzymology , Polymerization , Zebrafish
4.
Chem Mater ; 34(6): 2752-2763, 2022 Mar 22.
Article En | MEDLINE | ID: mdl-35360437

Injectable bioelectronics could become an alternative or a complement to traditional drug treatments. To this end, a new self-doped p-type conducting PEDOT-S copolymer (A5) was synthesized. This copolymer formed highly water-dispersed nanoparticles and aggregated into a mixed ion-electron conducting hydrogel when injected into a tissue model. First, we synthetically repeated most of the published methods for PEDOT-S at the lab scale. Surprisingly, analysis using high-resolution matrix-assisted laser desorption ionization-mass spectroscopy showed that almost all the methods generated PEDOT-S derivatives with the same polymer lengths (i.e., oligomers, seven to eight monomers in average); thus, the polymer length cannot account for the differences in the conductivities reported earlier. The main difference, however, was that some methods generated an unintentional copolymer P(EDOT-S/EDOT-OH) that is more prone to aggregate and display higher conductivities in general than the PEDOT-S homopolymer. Based on this, we synthesized the PEDOT-S derivative A5, that displayed the highest film conductivity (33 S cm-1) among all PEDOT-S derivatives synthesized. Injecting A5 nanoparticles into the agarose gel cast with a physiological buffer generated a stable and highly conductive hydrogel (1-5 S cm-1), where no conductive structures were seen in agarose with the other PEDOT-S derivatives. Furthermore, the ion-treated A5 hydrogel remained stable and maintained initial conductivities for 7 months (the longest period tested) in pure water, and A5 mixed with Fe3O4 nanoparticles generated a magnetoconductive relay device in water. Thus, we have successfully synthesized a water-processable, syringe-injectable, and self-doped PEDOT-S polymer capable of forming a conductive hydrogel in tissue mimics, thereby paving a way for future applications within in vivo electronics.

5.
Adv Sci (Weinh) ; 9(2): e2101711, 2022 01.
Article En | MEDLINE | ID: mdl-34741447

There is increasing demand for direct in situ metabolite monitoring from cell cultures and in vivo using implantable devices. Electrochemical biosensors are commonly preferred due to their low-cost, high sensitivity, and low complexity. Metabolite detection, however, in cultured cells or sensitive tissue is rarely shown. Commonly, glucose sensing occurs indirectly by measuring the concentration of hydrogen peroxide, which is a by-product of the conversion of glucose by glucose oxidase. However, continuous production of hydrogen peroxide in cell media with high glucose is toxic to adjacent cells or tissue. This challenge is overcome through a novel, stacked enzyme configuration. A primary enzyme is used to provide analyte sensitivity, along with a secondary enzyme which converts H2 O2 back to O2 . The secondary enzyme is functionalized as the outermost layer of the device. Thus, production of H2 O2 remains local to the sensor and its concentration in the extracellular environment does not increase. This "biostack" is integrated with organic electrochemical transistors to demonstrate sensors that monitor glucose concentration in cell cultures in situ. The "biostack" renders the sensors nontoxic for cells and provides highly sensitive and stable detection of metabolites.


Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Glucose/analysis , Glucose/metabolism , Hydrogen Peroxide/analysis , Hydrogen Peroxide/metabolism , Cells, Cultured , Humans
6.
Adv Mater ; 34(4): e2106235, 2022 Jan.
Article En | MEDLINE | ID: mdl-34658088

Organic electrochemical transistors (OECTs) hold promise for developing a variety of high-performance (bio-)electronic devices/circuits. While OECTs based on p-type semiconductors have achieved tremendous progress in recent years, n-type OECTs still suffer from low performance, hampering the development of power-efficient electronics. Here, it is demonstrated that fine-tuning the molecular weight of the rigid, ladder-type n-type polymer poly(benzimidazobenzophenanthroline) (BBL) by only one order of magnitude (from 4.9 to 51 kDa) enables the development of n-type OECTs with record-high geometry-normalized transconductance (gm,norm  ≈ 11 S cm-1 ) and electron mobility × volumetric capacitance (µC* ≈ 26 F cm-1  V-1 s-1 ), fast temporal response (0.38 ms), and low threshold voltage (0.15 V). This enhancement in OECT performance is ascribed to a more efficient intermolecular charge transport in high-molecular-weight BBL than in the low-molecular-weight counterpart. OECT-based complementary inverters are also demonstrated with record-high voltage gains of up to 100 V V-1 and ultralow power consumption down to 0.32 nW, depending on the supply voltage. These devices are among the best sub-1 V complementary inverters reported to date. These findings demonstrate the importance of molecular weight in optimizing the OECT performance of rigid organic mixed ionic-electronic conductors and open for a new generation of power-efficient organic (bio-)electronic devices.

7.
Bioact Mater ; 10: 107-116, 2022 Apr.
Article En | MEDLINE | ID: mdl-34901533

Leveraging the biocatalytic machinery of living organisms for fabricating functional bioelectronic interfaces, in vivo, defines a new class of micro-biohybrids enabling the seamless integration of technology with living biological systems. Previously, we have demonstrated the in vivo polymerization of conjugated oligomers forming conductors within the structures of plants. Here, we expand this concept by reporting that Hydra, an invertebrate animal, polymerizes the conjugated oligomer ETE-S both within cells that expresses peroxidase activity and within the adhesive material that is secreted to promote underwater surface adhesion. The resulting conjugated polymer forms electronically conducting and electrochemically active µm-sized domains, which are inter-connected resulting in percolative conduction pathways extending beyond 100 µm, that are fully integrated within the Hydra tissue and the secreted mucus. Furthermore, the introduction and in vivo polymerization of ETE-S can be used as a biochemical marker to follow the dynamics of Hydra budding (reproduction) and regeneration. This work paves the way for well-defined self-organized electronics in animal tissue to modulate biological functions and in vivo biofabrication of hybrid functional materials and devices.

8.
Adv Sci (Weinh) ; 7(15): 2000641, 2020 Aug.
Article En | MEDLINE | ID: mdl-32775155

Extracellular electron transfer (EET) denotes the process of microbial respiration with electron transfer to extracellular acceptors and has been exploited in a range of microbial electrochemical systems (MESs). To further understand EET and to optimize the performance of MESs, a better understanding of the dynamics at the microscale is needed. However, the real-time monitoring of EET at high spatiotemporal resolution would require sophisticated signal amplification. To amplify local EET signals, a miniaturized bioelectronic device, the so-called organic microbial electrochemical transistor (OMECT), is developed, which includes Shewanella oneidensis MR-1 integrated onto organic electrochemical transistors comprising poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) combined with poly(vinyl alcohol) (PVA). Bacteria are attached to the gate of the transistor by a chronoamperometric method and the successful attachment is confirmed by fluorescence microscopy. Monitoring EET with the OMECT configuration is achieved due to the inherent amplification of the transistor, revealing fast time-responses to lactate. The limits of detection when using microfabricated gates as charge collectors are also investigated. The work is a first step toward understanding and monitoring EET in highly confined spaces via microfabricated organic electronic devices, and it can be of importance to study exoelectrogens in microenvironments, such as those of the human microbiome.

9.
Sci Rep ; 9(1): 10844, 2019 07 26.
Article En | MEDLINE | ID: mdl-31350439

Continuous glucose monitoring from sweat and tears can improve the quality of life of diabetic patients and provide data for more accurate diagnosis and treatment. Current continuous glucose sensors use enzymes with a one-to-two week lifespan, which forces periodic replacement. Metal oxide sensors are an alternative to enzymatic sensors with a longer lifetime. However, metal oxide sensors do not operate in sweat and tears because they function at high pH (pH > 10), and sweat and tears are neutral (pH = 7). Here, we introduce a non-enzymatic metal oxide glucose sensor that functions in neutral fluids by electronically inducing a reversible and localized pH change. We demonstrate glucose monitoring at physiologically relevant levels in neutral fluids mimicking sweat, and wireless communication with a personal computer via an integrated circuit board.


Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Electrochemical Techniques/instrumentation , Electrochemical Techniques/methods , Glucose/analysis , Sweat/chemistry , Tears/chemistry , Cobalt/chemistry , Diabetes Mellitus/metabolism , Electrodes , Glucose/metabolism , Gold/chemistry , Humans , Hydrogen-Ion Concentration , Oxides/chemistry , Palladium/chemistry , Quality of Life , Silver/chemistry , Silver Compounds/chemistry
10.
Adv Sci (Weinh) ; 6(7): 1800935, 2019 Apr 03.
Article En | MEDLINE | ID: mdl-30989015

Bioelectronic devices that modulate pH can affect critical biological processes including enzymatic activity, oxidative phosphorylation, and neuronal excitability. A major challenge in controlling pH is the high buffering capacity of many biological media. To overcome this challenge, devices need to be able to store and deliver a large number of protons on demand. Here, a bioelectronic modulator that controls pH using palladium nanoparticles contacts with high surface area as a proton storage medium is developed. Reversible electronically triggered acidosis (low pH) and alkalosis (high pH) in physiologically relevant buffer conditions are achieved. As a proof of principle, this new platform is used to control the degradation and fluorescence of acid sensitive polymeric microparticles loaded with a pH sensitive fluorescent dye.

11.
ACS Appl Mater Interfaces ; 10(26): 21782-21787, 2018 Jul 05.
Article En | MEDLINE | ID: mdl-29905062

Biological systems exchange information often with chemical signals. Here, we demonstrate the chemical delivery of a fluorescent label using a bioelectronic trigger. Acid-sensitive microparticles release fluorescin diacetate upon low pH induced by a bioelectronic device. Cardiac fibroblast cells (CFs) uptake fluorescin diacetate, which transforms into fluorescein and emits a fluorescent signal. This proof-of-concept bioelectronic triggered delivery may be used in the future for real-time programming and control of cells and cell systems.

12.
Adv Mater ; 30(5)2018 Feb.
Article En | MEDLINE | ID: mdl-29266473

Organic electrochemical transistors (OECTs) are promising transducers for biointerfacing due to their high transconductance, biocompatibility, and availability in a variety of form factors. Most OECTs reported to date, however, utilize rather large channels, limiting the transistor performance and resulting in a low transistor density. This is typically a consequence of limitations associated with traditional fabrication methods and with 2D substrates. Here, the fabrication and characterization of OECTs with vertically stacked contacts, which overcome these limitations, is reported. The resulting vertical transistors exhibit a reduced footprint, increased intrinsic transconductance of up to 57 mS, and a geometry-normalized transconductance of 814 S m-1 . The fabrication process is straightforward and compatible with sensitive organic materials, and allows exceptional control over the transistor channel length. This novel 3D fabrication method is particularly suited for applications where high density is needed, such as in implantable devices.

13.
Adv Sci (Weinh) ; 4(7): 1600527, 2017 07.
Article En | MEDLINE | ID: mdl-28725527

From cell-to-cell communication to metabolic reactions, ions and protons (H+) play a central role in many biological processes. Examples of H+ in action include oxidative phosphorylation, acid sensitive ion channels, and pH dependent enzymatic reactions. To monitor and control biological reactions in biology and medicine, it is desirable to have electronic devices with ionic and protonic currents. Here, we summarize our latest efforts on bioprotonic devices that monitor and control a current of H+ in physiological conditions, and discuss future potential applications. Specifically, we describe the integration of these devices with enzymatic logic gates, bioluminescent reactions, and ion channels.

14.
Adv Healthc Mater ; 5(17): 2295-302, 2016 09.
Article En | MEDLINE | ID: mdl-27385673

A compact multianalyte biosensing platform is reported, composed of an organic electrochemical transistor (OECT) microarray integrated with a pumpless "finger-powered" microfluidic, for quantitative screening of glucose, lactate, and cholesterol levels. A biofunctionalization method is designed, which provides selectivity towards specific metabolites as well as minimization of any background interference. In addition, a simple method is developed to facilitate multi-analyte sensing and avoid electrical crosstalk between the different transistors by electrically isolating the individual devices. The resulting biosensing platform, verified using human samples, offers the possibility to be used in easy-to-obtain biofluids with low abundance metabolites, such as saliva. Based on our proposed method, other types of enzymatic biosensors can be integrated into the array to achieve multiplexed, noninvasive, personalized point-of-care diagnostics.


Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Fingers , Lab-On-A-Chip Devices , Saliva/metabolism , Transistors, Electronic , Female , Humans , Male
15.
Nat Commun ; 7: 11287, 2016 Apr 19.
Article En | MEDLINE | ID: mdl-27090156

Poly(3,4-ethylenedioxythiophene) doped with poly(styrenesulfonate), PEDOT: PSS, has been utilized for over two decades as a stable, solution-processable hole conductor. While its hole transport properties have been the subject of intense investigation, recent work has turned to PEDOT: PSS as a mixed ionic/electronic conductor in applications including bioelectronics, energy storage and management, and soft robotics. Conducting polymers can efficiently transport both holes and ions when sufficiently hydrated, however, little is known about the role of morphology on mixed conduction. Here, we show that bulk ionic and electronic mobilities are simultaneously affected by processing-induced changes in nano- and meso-scale structure in PEDOT: PSS films. We quantify domain composition, and find that domain purification on addition of dispersion co-solvents limits ion mobility, even while electronic conductivity improves. We show that an optimal morphology allows for the balanced ionic and electronic transport that is critical for prototypical mixed conductor devices. These findings may pave the way for the rational design of polymeric materials and processing routes to enhance devices reliant on mixed conduction.

16.
J Mater Chem B ; 4(29): 4952-4968, 2016 Aug 07.
Article En | MEDLINE | ID: mdl-32264022

The polydioxythiophenes PEDOT and more recently ProDOT have emerged as champion materials in the field of organic bioelectronics, both in the domain of biosensing and also for integration with living cells (both in vitro and in vivo). Although polydioxythiophenes in their pristine forms have shown great promise for bioelectronics, in order to broaden the spectrum of applications, a biofunctionalization step is essential. In this review we summarise the methods that have been used thus far to biofunctionalize polydioxythiophenes in an effort to improve the biotic/abiotic interface. We provide an introduction to this class of materials, focusing particularly on the different methods of synthesis (chemical oxidative polymerization, vapor phase polymerization or direct electrochemical polymerization) and discuss the implications of synthesis on biofunctionalization. Rather than provide an exhaustive review, we chose to highlight key examples of biofunctionalization techniques for polydioxythiophenes for specific biomedical applications. Finally, we conclude with a brief discussion of the importance of biofunctionalization methods in future bioelectronics applications, and some ideas for future directions in this field.

17.
Sci Adv ; 1(4): e1400251, 2015 May.
Article En | MEDLINE | ID: mdl-26601178

Despite recent interest in organic electrochemical transistors (OECTs), sparked by their straightforward fabrication and high performance, the fundamental mechanism behind their operation remains largely unexplored. OECTs use an electrolyte in direct contact with a polymer channel as part of their device structure. Hence, they offer facile integration with biological milieux and are currently used as amplifying transducers for bioelectronics. Ion exchange between electrolyte and channel is believed to take place in OECTs, although the extent of this process and its impact on device characteristics are still unknown. We show that the uptake of ions from an electrolyte into a film of poly(3,4-ethylenedioxythiophene) doped with polystyrene sulfonate ( PEDOT: PSS) leads to a purely volumetric capacitance of 39 F/cm(3). This results in a dependence of the transconductance on channel thickness, a new degree of freedom that we exploit to demonstrate high-quality recordings of human brain rhythms. Our results bring to the forefront a transistor class in which performance can be tuned independently of device footprint and provide guidelines for the design of materials that will lead to state-of-the-art transistor performance.

18.
Adv Healthc Mater ; 3(9): 1377-80, 2014 Sep.
Article En | MEDLINE | ID: mdl-24591460

The integration of an ionic liquid gel on conformal electrodes is investigated for applications in long-term cutaneous recordings. Electrodes made of Au and the conducting polymer PEDOT:PSS coated with the gel show a low impedance in contact with the skin that maintains a steady value over several days, paving the way for non-invasive, long-term monitoring of human electrophysiological activity.


Electric Impedance , Electrodes , Electrophysiology/instrumentation , Gels/chemistry , Ionic Liquids/chemistry , Electrophysiological Phenomena/physiology , Equipment Design , Forearm/physiology , Gold/chemistry , Humans , Polystyrenes/chemistry , Thiophenes/chemistry
19.
J Mater Chem B ; 2(17): 2537-2545, 2014 May 07.
Article En | MEDLINE | ID: mdl-32261421

For the majority of biosensors or biomedical devices, immobilization of the biorecognition element is a critical step for device function. To achieve longer lifetime devices and controllable functionalization, covalent immobilisation techniques are preferred over passive adhesion and electrostatic interactions. The rapidly emerging field of organic bioelectronics uses conducting polymers (or small molecules) as the active materials for transduction of the biological signal to an electronic one. While a number of techniques have been utilized to entrap or functionalize conducting polymers deposited by electro- or vapor phase polymerization, covalent functionalization of solution processed films, essential for realizing low cost or high throughput fabrication, has not been thoroughly investigated. In this study we show a versatile biofunctionalization technique for the solution processable conducting polymer poly(3,4-ethylenedioxythiophene) doped with poly(styrenesulfonate) PEDOT:PSS, which is a commercially available material, and has a record high conductivity. Addition of poly(vinyl alcohol) (PVA) into the solution with PEDOT:PSS provides a handle for subsequent silanization with a well-characterised silane reagent, allowing for covalent linkage of biological moieties onto PEDOT:PSS films. We show homogenous and large-scale biofunctionalization with polypeptides and proteins, as well as maintenance of the biological functionalities of the proteins. In addition, no deleterious effects are noted on the electronic or ionic transport properties of the conducting polymer films due to incorporation of the PVA.

20.
J Mater Chem B ; 1(31): 3860-3867, 2013 Aug 21.
Article En | MEDLINE | ID: mdl-32261140

Conducting polymers (CPs) are increasingly being used to interface with cells for applications in both bioelectronics and tissue engineering. To facilitate this interaction, cells need to adhere and grow on the CP surface. Extracellular matrix components are usually necessary to support or enhance cell attachment and growth on polymer substrates. Here we show the preparation of PEDOT(TOS):gelatin composites as a new biocompatible substrate for use in tissue engineering. Gelatin, a derivative of the extracellular matrix protein collagen, was incorporated into poly(3,4 ethylenedioxythiophene)-tosylate (PEDOT(TOS)) films via vapour phase polymerisation (VPP) without changing the electrochemical properties of the CP. Further, gelatin, incorporated into the PEDOT(TOS) film, was found to specifically support bovine brain capillary endothelial cell adhesion and growth, indicating that the functionality of the biomolecule was maintained. The biocompatibility of the composite films was demonstrated indicating the significant future potential of biocomposites of this type for use in promoting cell adhesion in electrically active materials for tissue engineering.

...